> For the complete documentation index, see [llms.txt](https://infosys.selmotech.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://infosys.selmotech.com/selmo-solution/selmo-solution-en/selmo-templates-and-tools/selmo-operation-and-control-concept-md.md).

# Selmo operation and control concept (md)

## Selmo operating and control concept

### Structure, function and safety

*(Basis for operating instructions according to ISO/IEC 82079-1)*

***

### 1. Purpose of the document

This chapter describes the machine's operating and control concept, whose control system is based on the **Selmo method (Sequence Logic Modelling)** It serves to explain the logical mode of operation, the safety mechanisms and the interaction between operator, machine and control.

***

### 2. Target audience

This documentation is intended for:

* Machine operators and plant operators
* Maintenance personnel and service technicians
* Inspectors, auditors and CE officers
* Integrators and software engineers who work with Selmo Studio

***

### 3. Overview of the system principle

The machine control follows the principle of **deterministic sequence control (Selmo SEQ)**.

**Key features:**

* The control works with **states** instead of individual commands.
* At any time **only one state is active**.
* Transition to the next state occurs **only when all defined conditions are met**.

This structure ensures reproducible, traceable and safe behavior of the machine.

***

### 4. Control architecture

#### 4.1 Structure of the layers

The control is hierarchically structured into:

1. **Plant (entire system)** – describes the logical overall structure of the machine.
2. **Hardware zones (HWZ)** – physical areas with their own control logic (e.g. stations, modules).
3. **Sequences (SEQ)** – sequence controls within an HWZ.
4. **Zones (Zone Types)** – logical function blocks that map real signals or virtual functions.

***

#### 4.2 The switching engine (Sequence Engine)

The switching engine is the sequence and clock generator.\
It continuously checks three core conditions:

| Input quantity                  | Meaning                       |
| ------------------------------- | ----------------------------- |
| **AR (Auto Release)**           | Automatic release active      |
| **¬I (No Interlock)**           | no safety violation           |
| **ΣS (Sum of Sequence Checks)** | all ongoing actions completed |

Only when **AR = 1 ∧ ¬I ∧ ΣS = 0**, the state change occurs.\
This ensures that the sequence is only continued in a safe state.

***

### 5. Zone level and behavior

#### 5.1 Definition

Zones are standardized switching elements that bundle actions and feedback.\
They establish the connection between logic and physics.

***

#### 5.2 Zone types

| Type        | Description       | Example                     |
| ----------- | ----------------- | --------------------------- |
| **IN**      | Input signal      | Start button, sensor        |
| **OUT**     | Output signal     | Lamp, valve                 |
| **IN\_OUT** | Action + feedback | Cylinder, axis, calculation |
| **MEM**     | Memory zone       | Software status, parameter  |

***

#### 5.3 Operants (Bit-Control)

Each zone has an assigned function in each state.

| Operant                | Meaning               | Effect                          |
| ---------------------- | --------------------- | ------------------------------- |
| **S (Sequence Check)** | Action active         | waiting for feedback            |
| **I (Interlock)**      | Safety monitoring     | stops sequence in case of error |
| **M (Monitoring)**     | Diagnostic monitoring | reports notice without stop     |
| **0 (Don’t Care)**     | inactive              | no function in this state       |

This assignment is defined in the **System Layer** in Selmo Studio.

***

### 6. Safety functions

The system contains several standardized safety mechanisms:

1. **Interlock function** – detects safety violations and stops the sequence.
2. **PairCheck** – monitors contradictory feedback (e.g. cylinder front/back).
3. **MXIC (Manual Cross Interlock)** – prevents unsafe hand movements.
4. **Monitoring (M)** – provides diagnostic messages without interrupting the process.

All safety functions are an integral part of the Selmo standard – no additional programming required.

***

### 7. Operation via the HMI

The user interface shows:

* the active state
* active zones with color coding
* plain text HMI messages
* error and diagnostic lists

**Color coding:**

| Color     | Meaning            |
| --------- | ------------------ |
| 🟩 Green  | AutoRelease active |
| 🟥 Red    | Interlock          |
| 🟨 Yellow | Warning            |
| ⚪ Grey    | Manual Mode        |

The HMI also serves as an operating interface, diagnostic tool and documentation view.

***

### 8. Behavior in case of malfunctions

If a zone reports a deviation:

1. The sequence is automatically stopped.
2. The affected zone is marked in red.
3. An error message with cause appears on the HMI.
4. After error correction and release (AR = 1) the control resumes the sequence.

This ensures that no uncontrolled movements occur and that every error can be localized.

***

### 9. Documentation and traceability

The Selmo structure documents itself:

* Every state, every zone and every operant are stored in the model.
* HMI texts and diagnostics are generated automatically.
* Changes are versionable and auditable.

In this way, the control meets the requirements for traceability, CE conformity and quality assurance.

***

### 10. Summary

The Selmo structure defines a clearly traceable and safe control system:

* formal state description (deterministic)
* standardized zone logic
* integrated safety functions
* automatic diagnostics and documentation

**Advantages:**

* Transparent processes
* Unambiguous error messages
* Safe operation
* Uniform structure for all systems

***

### 11. Reference

This concept is based on the Selmo standard according to the development guidelines of\
**Selmo Technology GmbH – Sequence Logic Modelling System (SEL\_SEQ\_STD-DE-V3.0)**

***

> **Note for documentation editors:**\
> This text is the static section of the operating manual.\
> Dynamic parts (state descriptions, HMI lists, sequence flows) are automatically supplemented from the model.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter, and the optional `goal` query parameter:

```
GET https://infosys.selmotech.com/selmo-solution/selmo-solution-en/selmo-templates-and-tools/selmo-operation-and-control-concept-md.md?ask=<question>&goal=<endgoal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is optional and describes the broader end goal you are ultimately trying to accomplish on behalf of the user. GitBook uses it to tailor the answer towards what is most useful for that goal.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.