> For the complete documentation index, see [llms.txt](https://infosys.selmotech.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://infosys.selmotech.com/selmo-solution/selmo-solution-en/selmo-as-a-process/selmo-ptf/ptf-checklists/selmo-ptf-output-and-customer-checklist.md).

# ✅ Selmo PTF – Output & Customer checklist

#### **1. Purpose of the checklist**

This checklist serves to **Ensure completeness, quality and usability** of all PTF results.\
It describes:

* Which **Outputs** arise from the PTF process,
* How they **are approved and distributed** Non-Selmo-compliant technologies can be identified
* And which **Customer (Stakeholder)** use the results in which form **use**.

***

### **2. Output checklist**

| No. | PTF output                            | Description                                                                | Mandatory / optional | Format               | Released by                   | Check criteria                            |
| --- | ------------------------------------- | -------------------------------------------------------------------------- | -------------------- | -------------------- | ----------------------------- | ----------------------------------------- |
| 1   | **PTF report (complete document)**    | Summary of all PTF results (Process, Technology, Function)                 | Mandatory            | PDF / DOCX           | Project management / PTF lead | Complete, consistent, approved            |
| 2   | **PTF model data (structural model)** | Exported machine model (Plant → HWZ → Sequence → Zones → Bit-Control)      | Mandatory            | XML / PLCopen / JSON | Automation / PTF lead         | Structure complete, importable into Selmo |
| 3   | **PTF-RISK**                          | Risk assessment of all deviations and non-Selmo conformities               | Mandatory            | Excel / PDF          | Quality / Safety              | Risks assessed, measures defined          |
| 4   | **PTF-RELEASE**                       | Formal approval for implementation (signatures of all responsible parties) | Mandatory            | PDF                  | Project management / customer | Signed, approved, versioned               |
| 5   | **PTF-FUNC**                          | Complete function sheets (inputs, outputs, limits, test cases)             | Mandatory            | XML / PDF            | Automation / Quality          | Testable, tested, documented              |
| 6   | **PTF-HMI**                           | Operating concept with HMI texts, colors, messages and diagnostics         | Optional             | CSV / JSON           | Maintenance / Quality         | HMI texts correctly assigned              |
| 7   | **PTF-TECH**                          | Technology matrix with components, media, interfaces                       | Mandatory            | Excel / PDF          | Mechanics / Electrical        | All components represented                |
| 8   | **PTF-IF**                            | Interface description to external systems (MES, ERP, SCADA)                | Mandatory            | JSON / YAML          | IT / OT                       | Communication structure defined           |
| 9   | **PTF-SAFE**                          | Safety logic (interlocks, CMZ, MXIC, PLr/SIL)                              | Mandatory            | Excel / PDF          | Safety / CE                   | Safety concept complete and traceable     |
| 10  | **PTF-Q**                             | Quality plan and test strategy (SPC, limit patterns, DoE)                  | Optional             | Excel / PDF          | Quality                       | Test processes defined                    |
| 11  | **PTF-FINAL / Lessons Learned**       | Documentation after completion (audit trail, improvements)                 | Optional             | PDF                  | PTF lead / Project management | Complete traceability                     |
| 12  | **PTF-NORM / Compliance**             | Proof of considered standards and guidelines (MVO 2027, ISO 12100 etc.)    | Mandatory            | PDF                  | Quality / CE                  | Standards listed, conformity assessed     |

***

#### **3. Testing and approval criteria for outputs**

Before approval the following points must be met:

* [ ] All PTF artifacts are available in the current version
* [ ] All documents are formally reviewed (technical & normative)
* [ ] No open risks without measures
* [ ] Approvals by all disciplines (Process, Technology, Function, Quality, Project Management)
* [ ] Import into Selmo-Studio successfully validated
* [ ] Deviation list has been processed or accepted
* [ ] PTF release document is available signed

***

#### **4. Distribution / storage of outputs**

**Recommended directory structure:**

* **/PTF/Output/**
  * PTF-Report\_v1.0.pdf
  * PTF-Model\_v1.0.xml
  * PTF-RISK\_v1.0.xlsx
  * PTF-RELEASE\_v1.0.pdf
  * PTF-FUNC\_v1.0.xml
  * PTF-SAFE\_v1.0.xlsx
  * PTF-HMI\_v1.0.csv
  * PTF-IF\_v1.0.json
  * PTF-NORM\_v1.0.pdf

**Distribution recommendation:**

* All stakeholders receive access via a central repository (e.g., Git, SharePoint, PLM system).
* Only approved documents may be distributed (status: *Released*).
* Archiving requirement for every approved version.

***

### **5. Customer checklist**

This overview describes, **who uses the PTF results**, **for what**, and **which concrete benefit** they derive from it.

| No. | Customer / Stakeholder            | Uses / requires                          | Purpose                                   | Benefit                                         | Responsible for feedback |
| --- | --------------------------------- | ---------------------------------------- | ----------------------------------------- | ----------------------------------------------- | ------------------------ |
| 1   | **Project management / PTF lead** | Entire PTF report, PTF-RISK, PTF-RELEASE | Project control, Quality, Decision-making | Transparency, control, traceability             | Project management       |
| 2   | **Process owner (IE)**            | PTF-PROC, PTF-PARAM, PTF-FUNC            | Process validation, parameter alignment   | Process quality, early fault detection          | Process owner            |
| 3   | **Mechanics / Design**            | PTF-TECH, PTF-IO                         | Implementation and layout coordination    | Avoidance of design errors                      | mechanics                |
| 4   | **Electrical / control**          | PTF-IO, PTF-SAFE, PTF-IF                 | Hardware integration, addressing          | Clear assignment of signals                     | Electrical               |
| 5   | **Software / automation**         | PTF-FUNC, PTF model data                 | Creation of the Selmo process model       | Deterministic programming, code traceability    | Automation               |
| 6   | **Quality / Safety / CE**         | PTF-RISK, PTF-SAFE, PTF-NORM             | Audit, risk assessment, CE documentation  | Standards compliance, demonstrability           | Quality / CE             |
| 7   | **IT / OT / MES / ERP**           | PTF-IF, PTF model data                   | Communication and data integration        | Early system tests, stable data exchange points | IT / OT                  |
| 8   | **Operation / Maintenance**       | PTF-HMI, PTF-FUNC, PTF-RISK              | Operation, diagnosis, training            | Transparent maintenance, reduced downtime       | Maintenance              |
| 9   | **Management / Controlling**      | PTF-Report, PTF-RISK, PTF-RELEASE        | Economic evaluation, governance           | Project decisions, budget transparency          | Management               |
| 10  | **Customer / Operator**           | PTF-Report, PTF-NORM, PTF-FINAL          | Acceptance, operation, audit              | Trust, proof of safety and quality              | Customer / Operator      |

***

#### **6. Approval and communication process**

1. **PTF outputs created** → by specialist departments
2. **Internal review** → by PTF lead, Quality and Safety
3. **Review meeting** → all disciplines present
4. **Deviations documented** → PTF-RISK updated
5. **Approval** → PTF-RELEASE signed
6. **Distribution** → central storage + access for all customers
7. **Feedback / Lessons Learned** → collected in PTF-FINAL

***

#### **7. Use of outputs during the project**

| Phase                        | Use of the outputs                                   |
| ---------------------------- | ---------------------------------------------------- |
| **After PTF release**        | Basis for Selmo modeling and digital twin            |
| **During design**            | Reference for signal definition and hardware concept |
| **Before commissioning**     | Preparation SoftFAT / simulation                     |
| **During operation**         | Use of HMI, diagnostics, parameter management        |
| **In audit / CE inspection** | Proof of standards compliance                        |
| **In service**               | Fault diagnosis, change management                   |

***

#### **8. Completion criteria for the output**

A PTF is considered **fully completed**, when:

* All PTF documents are created, reviewed and approved
* The PTF report is archived as version “Released”
* The Selmo model can be imported without deviations
* All deviations are assessed and documented
* The customer / operator has acknowledged or confirmed the results

***

#### **9. Conclusion**

The **Output** of the PTF is not a paper document, but a **digital twin of the machine logic** –\
complete, verifiable and deterministic.

The **Customer** receive from it:

* **Process clarity** (Process & logic visible),
* **Risk transparency** (assessed & documented),
* **equivalent** (from requirement to behavior),
* **trust** (through standards compliance & data quality).

> The PTF output is the **link between engineering and operations**,\
> and the basis for **Software, audit, quality and digital simulation** in the Selmo system.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter, and the optional `goal` query parameter:

```
GET https://infosys.selmotech.com/selmo-solution/selmo-solution-en/selmo-as-a-process/selmo-ptf/ptf-checklists/selmo-ptf-output-and-customer-checklist.md?ask=<question>&goal=<endgoal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is optional and describes the broader end goal you are ultimately trying to accomplish on behalf of the user. GitBook uses it to tailor the answer towards what is most useful for that goal.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.